Table 13-92
HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus
DeviceOperationalStatusPrevious
Table 13-93
HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name
CIM_Indication
IndicationIdentifier
PerceivedSeverity
IndicationTime
CIM_AlertIndication
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
HP_AlertIndication
Summary
Property implementation
Current OperationStatus values for Storage Volume
•
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Previous OperationStatus values for Storage Volume
•
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Property implementation
GUID string generated at indication
2 (Info)
Time of indication
Logical Drive is in a degraded state. Device is still
servicing I/O but redundancy may be degraded or
lost.
WBEM path of the HPSA_StorageVolume class
2 (CIMObjectPath)
5 (Device Alert)
1203
SmartArray
Please allow time for recovery operation to complete.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
Logical Drive is in a degraded state.
12BSmart Array 209