Table 15-78
HPSAS_DeviceIndication: Logical Drive status ERROR
Property name
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
Table 15-79
HPSAS_DeviceIndication: Logical Drive is in a degraded state
Property name
CIM_Indication
IndicationIdentifier
PreceivedSeverity
IndicationTime
CIM_AlertIndication
Description
AlertingMangedElement
AlertingElementFormat
AlertType
Property implementation
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Property implementation
GUID string generated at the time of indication
3 (Warning)
Time of indication
A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or
lost.
WBEM Path of Storage Volume
2 (CIMObjectPath)
5 (Device Alert)
14BSAS HBA 320