PLC-ET30L Expand Serial Command Functional Specifications

9.8 Screen Status Read Command

9.8.1 CR_SCREEN Command

Command
"CR_SCREEN" [CR]
Details
Get selected screen image size
Acceptable
%1
Response
Unacceptable

9.8.2 CR_ KYSTNMODE Command

Command
"CR_KYSTNMODE" [CR]
Details
Get setting status of Keystone Store Mode
Acceptable
Response
%1
Unacceptable

9.8.3 CR_VSCALE Command

Command
"CR_VSCALE" [CR]
Details
Get setting status of V scale
Acceptable
Response
%1
Unacceptable

9.8.4 CR_VPOS Command

Command
"CR_VPOS" [CR]
Details
Get setting status of V Position
Acceptable
Response
%1
Unacceptable

9.8.5 CR_HSCALE Command

Command
"CR_HSCALE" [CR]
Details
Get setting status of H scale
Acceptable
Response
%1
Unacceptable
"000_%1" [CR]
"NORMAL" ---------------------- Normal mode
"WIDE" --------------------------- Wide mode
"FULL" --------------------------- Full mode
"TRUE" --------------------------- True mode
"CUSTOM" ----------------------- Custom mode
"Error Code" [CR] --- When command is not available in the
given condition (such as being selected input).
"?" [CR] --- When unknown command is received
"000_%1" [CR]
"STR" ---------------------- Store mode is "Store"
"RST" ---------------------- Store mode is "Reset"
"?" [CR] -------------------- When unknown command is received
"000_%1" [CR]
"-32"ÿ "032"
"?" [CR] -------------------- When unknown command is received
"000_%1" [CR]
"-15"ÿ "015"
"?" [CR] -------------------- When unknown command is received
"000_%1" [CR]
"-32"ÿ "032"
"?" [CR] -------------------- When unknown command is received