PLC-ET30L Expand Serial Command Functional Specifications
3ÿ

Notes for communication

Expand Serial Command is defined as a single command per line that starts with "C" and ends with
carriage return (0x0D).
There are two types of commands; Functional Execution Commands and Status Read Command.
- Example of Functional Execution Command: "CF_BRIGHT_032" [CR]
- Example of Status Read Command: "CR_BRIGHT" [CR]
Note) "_" means a space
When it takes more than a second to receive a single command, it is not executed.
When it takes more than a second to receive carriage return (0x0D) since the reception of the first
data "C", it clears the information of the receive buffer.
When the command pipelining, allow the interval time of no less than100ms after receiving return
value.
PC ! '
Projector
Projector ! '
PC
Do not send another command before the reception of the return value; the operation by the
commond is not ensured.
However this is not the case when no response is returned after more than 5 seconds.
It takes about 5 seconds for internal initialization after plugging in AC power. During this time, it
cannot process commands. Do not issue any command.
4ÿ

Notation Convention

Data from a controller to a projector is represented as COMMAND, and data from a projector to a
controller in response to the incoming command is represented as RESPONSE.
[CR]: Carriage Return Code
Carriage Return code is added to the end of the command.
Response is also followed by carriage return code.
_: Space Code
Space Code is represented as (_).
%1: Parameter included in Command
When there are more than one parameter, they are defined as %2, %3...
%%%: Error Code returned from a projector
Acceptable: "000".
Unacceptable: See [7. Error Code Table].
Command
"CF_BRIGHT_032" CR
(
A few ms - 5s)
(No less than 100 ms)
Next command
"000"
CR
Return Value