14. Replace the side cover (see "Replacing the side cover" on page 47).
15. Reconnect the external cables and power cords; then, turn on the attached

Power and signal cables for internal drives

Your computer uses cables to connect IDE and SCSI devices to the power supply
and to the system board. (See "System-board internal connectors" on page 32 for
the location of system-board connectors.) Review the following information before
connecting power and signal cables to internal drives:
v The drives that are preinstalled in your computer come with power and signal
v When you install a drive, ensure that one of the drive connectors of the signal
v If you have only one IDE device on a cable, it must be set as a master device.
v If two IDE devices are used on a single cable, one must be designated as the
v If two IDE devices are on a single cable and only one is a hard disk drive, the
The following cables are provided:
v Power cables: Four-wire power cables connect the drives to the power supply.
v Signal cables: Signal cables are typically flat cables, also called ribbon cables,
44
IBM IntelliStation M Pro Type 6219: User's Guide
devices and the computer.
cables attached. If you replace any drives, remember which cable is attached to
which drive.
cable is connected to the drive and that the connector at the other end of the
signal cable is connected to the system board.
master device and the other as the subordinate device; otherwise, the computer
might not recognize some of the IDE devices. The master and subordinate
designation is determined by switch or jumper settings on each IDE device.
hard disk drive must be set as a master device.
At the end of these cables are plastic connectors that can be attached to
different drives; these connectors vary in size.
that connect IDE, SCSI, and diskette drives to the system board. Two or three
types of signal cable come with your computer:
– IDE: The wider IDE signal cable has three connectors. One of these
connectors is attached to the drive, one is a spare, and the third is attached to
the master or subordinate IDE connector on the system board. The spare
connector can be used to connect additional IDE drives to your computer.
The CD-ROM drive is attached an ATA 100 signal cable. ATA 100 signal
cables are color-coded. The blue connector is attached to the system board.
The black connector is attached to the master IDE device. The gray middle
connector is attached to the subordinate IDE device. If you are installing an
additional hard disk drive, you must change the switch or jumper setting on
the CD-ROM drive to make the drive a subordinate device, set the switch or
jumper setting on the new drive to master, and change the connector used for
the CD-ROM drive to the gray middle connector. The new drive will be
connected to the black master IDE device connector.
– Diskette drive: The narrower signal cable has two connectors. One is
attached to the diskette drive, and the other is attached to the connector
(FDD1) on the system board.
– SCSI: The following cables can be used to attach SCSI devices to the
integrated SCSI controller on the system board:
- An Ultra320 twisted ribbon cable connects the internal Ultra320 SCSI hard
disk drive to the SCSI connector on the system board. This cable has four
additional connectors for attaching more internal SCSI devices.