Error code/symptom
001-250-000 (Failed system board ECC)
001-250-001 (Failed Processor Board ECC) v System board
001-292-000 (Core system: failed/CMOS
checksum failed)
005-XXX-000 (Failed Video test)
011-XXX-000 (Failed COM1 Serial Port
test)
011-XXX-001 (Failed COM2 Serial Port
test)
014-XXX-000 (Failed Parallel Port test)
015-XXX-001 (USB interface not found,
board damaged)
015-XXX-198 (Remote Supervisor Adapter
II installed) or (USB device connected
during USB test)
020-XXX-000 (Failed PCI Interface test)
030-XXX-000 (Failed Internal SCSI
interface test)
035-XXX-099 (No adapters were found)
035-XXX-S99 (Failed RAID test on PCI slot
S, check System Error Log before replacing
a FRU)
035-XXX-SNN (Check System Error Log
before replacing a FRU, NN = SCSI ID of
failing fixed disk)
035-253-S99 (RAID adapter initialization
failure)
089-XXX-001 (Failed Microprocessor test)
089-XXX-002 (Failed Optional
Microprocessor test)
FRU/action
v System board
v Load BIOS code defaults and rerun test.
1. Video adapter
2. System board
1. Check loopback plug connected to externalized serial port.
2. System board.
1. Check loopback plug connected to externalized serial port.
2. Check cable from externalized port to system board. Should
connect to serial port B on the system board (JCOM1).
3. System board.
v System board
v System board
1. If Remote Supervisor Adapter II is installed as an option,
remove it and rerun test.
Note: If Remote Supervisor Adapter II is present as a standard
installation, do not remove it; the test cannot be run.
2. Remove USB devices and rerun test.
3. System board
.
v System board
v System board
v If an adapter is installed re-check the connection.
1. RAID adapter
2. SCSI backplane
3. Cable
v Hard disk with SCSI ID NN on RAID adapter in PCI slot S.
1. ServeRAID Adapter in slot S is not configured properly. Obtain
the basic and extended configuration status and see the
ServeRAID Hardware Maintenance Manual for more
information.
2. Cable.
3. SCSI backplane.
4. Adapter.
1. Microprocessor 1
2. System board
1. Microprocessor 2
2. System board
Chapter 6. Symptom-to-FRU index