Step 6: Electrical Requirements, Connection & Grounding
Before installing,
turn power OFF at the service
panel. Lock service panel to prevent power from
being turned ON accidentally.
Chart
B:
E_eotriea_
Supply
Circuit
Requirements
MODEL
VOLTAGE
CIRCUITRATING
FREQUENCY
PHA8_=
304
120 VAC
10 Amps
60 Hz_
Single
366
120 VAC
10 Amps
60 Hz.
Single
364GL
120 VAC
10 Amps
60 Hz.
Single
364GE
120 VAC
20 Amps
60 Hz.
Single
For these
gas range
models,
a neutral
supply
wire must be provided
from the power
source
(breaker/fuse
panel) because critical range com-
ponents,
including
the surface
burner
spark re-
ignition
modules,
require
120 VAC
to operate
safely and properly. An improper
120 VAC power
supply
will cause
malfunction,
damage
to this
appliance,
and possibly
create
a condition
of
shock hazard. If the correct power supply circuit
is not provided,
it is the responsibility
and obliga-
tion of the installer and user to have proper power
supply
connected.
This must be accomplished
in accordance
with all applicable
local codes and
ordinances
by a qualified
electrician.
In the ab-
sence of local codes and ordinances,
the power
supply
connection
shall be in accordance
with
the National
Electrical
Code.
Observe
all governing
codes
and ordinances
when grounding.
In the absence
of these codes
or ordinances
observe
National
Electrical
Code
ANSI/NFPA
No. 70 current issue.
Electric
wiring
diagrams
and schematics
have
been placed in the toe kick area of the range for
access
by a qualified
service
technician.
Before you plug in an electrical
cord, be sure all
controls
are in the OFF position.
For appliances
equipped with a cord and plug, do
not cut or remove the ground
prong.
It must be
plugged
into a matching
grounding
type recep-
tacle to avoid
electrical
shock.
If there
is any
doubt as to whether
the wall receptacle
is prop-
erly
grounded,
the
customer
should
have
it
checked
by a qualified
electrician.
Installer
- show the owner
the location
of the
circuit breaker or fuse. Mark it for easy reference.
Dedicated
20 AMP service
is required
for range with electric
griddle.
CAUTION
The appliance
must be isolated from the gas supply piping system by closing its individual
manual shut-
off valve during any pressure
testing
of the gas supply piping system
at test pressures
equal to or less
than 1/2 psig (3.5kPa.).
The appliance
and its individual
shut off valve must be disconnected
from the gas supply piping system
during any pressure
testing of the system
at test pressures
in excess of 1/2 psig (3.5kPa.).
When checking
the manifold gas pressure,
the inlet pressure
to the regulator
should be at leas 6.0" (14.9
mb) W.C. for natural
gas or 11.0" (27.4 mb) for propane.
Do not attempt
any adjustment
of the pressure
regulator.
13