Step 2: Cabinet Preparation
GAS AND ELECTRIC
SUPPLY
FIG. 3A Gas & Electrical
Supply
Locations
for All Gas Ranges
1 3/4" maximum protrusion
from wall for gas or
electrical supply
electrical
gas
supply zone
supply zone
\
\
\
\
\\NN
\
\
\
-,
81/
\ \. \, \,
\ \
\.,
\
.
\
X\\\
_
,
_'-,
30 1/4" (30" models)
36 1/4" (36" models)
NOTE:
If not already
present,
install gas shut-off
valve in an easily accessible
location.
Make sure all
users know where and how to shut off the gas supply to the range.
NOTE: The installer should inform the consumer
of the location of the gas shut-off valve.
NOTE: An opening in the wall behind the appliance
and any opening in the floor under the appliance
must be
sealed.
The All Gas ranges may be connected
to the power supply with a range supply cord (supplied
with range)
or by hard-wiring
to the power supply.
It is the responsibility
of the installer to provide
the proper wiring
components
(cord or conduit and wires) and complete
the gas connection
as dictated
by local codes and
ordinances,
and/or the National
Electric
Code. The units must be properly
grounded.
Refer to Step 6 for
details.
The range must
be connected
only to the type of gas for which
it is certified.
If the range is to be
connected
to propane
gas, ensure that the propane
gas supply tank is equipped
with its own high
pressure
regulator
in addition
to the pressure
regulator
supplied with the range. (See STEP 5.)
NOTE: The range is designed for flush installation to the back of the wall.
For a successful
installation,
it may be necessary
to reposition the gas-
supply line and electrical
cords as the range is pushed back to its final
installed position.
IMPORTANT:
The cord supplied
with the gas ranges,
having
an electric
griddle,
requires
a NEMA
5-20 receptacle,
shown
here.
Local
codes
may
require a different
wiring method.
NEMA 5-20
RECEPTACLE
PLUG

Advertisement