PDG-DWL100 Expand Serial Command Functional Specifications
6.6
Lamp Status Read Command Table
Status read command
CR_LAMPREPL[CR]
CR_LAMPH [CR]
CR_LAMPMODE [CR]
CR_LAMPSTS [CR]
CR_PROJH [CR]
CR_HMLAMP [CR]
6.7
Sound Status Read Command Table
Status read command
CR_VOLUME [CR]
CR_MUTE [CR]
6.8
Setting Status Read Command Table
Status read command
CR_INPUTSEARCH [CR]
CR_LANG [CR]
CR_P-MANETIME [CR]
CR_SECURITY [CR]
CR_PJLOCKKNOW [CR]
CR_PJLOCKMENU [CR]
CR_RS232MODE [CR]
CR_STANDBYMODE[CR]
CR_CCAPTION [CR]
CR_FANCONTROL [CR]
CR_LAMPLIFERE [CR]
CR_RCODE [CR]
6.9
Other Status Read Command Table
Status read command
CR_STATUS [CR]
CR_SIGNAL [CR]
CR_VMUTE [CR]
CR_FREEZE [CR]
CR_TEMPWARN [CR]
CR_TEMPFAIL [CR]
CR_TEMP [CR]
Get information on Lamp replacement time
Get total Actuality used time of lamps
Get setting status of dimmer function level.
Get Lamp lighting status
Get total running time of projector
Get the total number of lamps
Get value of Volume.
Get setting status of Mute.
Item
Get setting status of Input search.
Get selected language
Get value of time when Power management
Get setting status of security
Get actual setting status of security
Get setting status of security of menu
Get setting status of RS232 mode
Get setting status of Standby mode.
Get setting status of Closed caption.
Get setting status of Fan control.
Get setting status of Lamp life Reminder.
Get selected Remote Control Code
Item
Get status of projector.
Get status of signal existence.
Get setting status of No Show.
Get setting status of Freeze
Get temperature status whether it is close to abnormal
level or not.
Get temperature in abnormal temperature status.
Get temperature status of now.
12 / 47
Item
Item