PDG-DWL100 Expand Serial Command Functional Specifications Overview 1ÿ 0û This Functional Specification defines communication with Network board for PDG- DWL100. 0û Commands are designed to Network communication, but most commands are also available to remote-control a projector through RS-232C from a computer. Therefore, commands are defined as Expand Serial Commands.
PDG-DWL100 Expand Serial Command Functional Specifications Notes for communication 3ÿ Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). When a projector receives carriage return (0x0D), it starts decoding. There are two types of commands;...
PDG-DWL100 Expand Serial Command Functional Specifications otation 4ÿ Data from a controller to a projector is represented as COMMAND, and responded data from a projector to a controller against the incoming command is represented as RESPONSE. [CR]: Carriage Return Code The command ends with carriage return code.
PDG-DWL100 Expand Serial Command Functional Specifications Functional Execution Command Table 5ÿ 5.1. Image Command Table Execute command Item CF_BRIGHT_%1[CR] Set value of Brightness CF_CONT_%1[CR] Set value of Contrast CF_COLOR_%1[CR] Set value of Color CF_SHARP_%1[CR] Set value of Sharpness CF_GAMMA_%1[CR] Set value of Gamma Correction CF_COLTEMP_%1[CR] Set level of Color Temperature CF_IMAGE_%1[CR]...
PDG-DWL100 Expand Serial Command Functional Specifications 5.6. Sound Command Table Execute command Item CF_VOLUME_%1[CR] Set value of Volume. CF_MUTE_%1[CR] Set ON/OFF of Sound Mute. 5.7. Setting Command Table Execute command Item CF_INPUTSEARCH_%1[CR] Set ON/OFF of Input search CF_LANG_%1[CR] Select language for OSD CF_P-MANETIME_%1[CR] Set timer for Power management CF_FDEFAULT_%1[CR]...
PDG-DWL100 Expand Serial Command Functional Specifications Status Read Command Table 6.1 Image Status Read Command Table Status read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_SHARP [CR] Get value of Sharpness CR_GAMMA [CR] Get value of Gamma...
PDG-DWL100 Expand Serial Command Functional Specifications Lamp Status Read Command Table Status read command Item CR_LAMPREPL[CR] Get information on Lamp replacement time CR_LAMPH [CR] Get total Actuality used time of lamps CR_LAMPMODE [CR] Get setting status of dimmer function level. CR_LAMPSTS [CR] Get Lamp lighting status CR_PROJH [CR]...
PDG-DWL100 Expand Serial Command Functional Specifications Error Code Table Error Code Contents -When the received data which cannot be decoded. -Parameter designation error (wrong digit number, including invalid value, etc.) Normal reception. (This is “Not” error.) Specified function is not available in the selected mode. Specified value is out of range.
PDG-DWL100 Expand Serial Command Functional Specifications Functional Execution CommandFormat PC issues a command in the format below: Pattern1: “CF_Command” [CR] Pattern2: “CF_Command_” %1 [CR] CF_: Header Command: Text %1: Parameter (Text) Space (To separate Command and Parameter) The projector decodes the received command and when it gets ready to receive another command, it returns the Correspondence.
PDG-DWL100 Expand Serial Command Functional Specifications Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “-50~050” --------------- Directly specify setting value of Brightness “UP” ---------------------- Increment setting value of Brightness by 1 “DN” ---------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness.
PDG-DWL100 Expand Serial Command Functional Specifications 8.4.5 CF_GAMMA Command Command “CF_GAMMA_%1” [CR] “000~003” ---------------- Directly specify setting value of Gamma “UP”---------------------- Increment setting value of Gamma by 1 “DN”---------------------- Decrement setting value of Gamma by 1 Set user controlled value of Gamma. Details (Available only in the normal Power ON status) No display is shown when projector received command...
PDG-DWL100 Expand Serial Command Functional Specifications 8.4.9 CF_TINT Command Command “CF_TINT_%1”[CR] “-50~050”------ Directly specify setting value of Tint. “UP”---- Set Tint to UP “DN”---- Set Tint to DN Set user controlled value of Tint. Details (Available only in the normal Power ON status) No display is shown when projector received command.
PDG-DWL100 Expand Serial Command Functional Specifications PC Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000~0031” ----------------- Directly specify setting value of Fine sync “UP” --------------------------- Increment setting value of Fine sync by 1 “DN” --------------------------- Decrement setting value of Fine sync by 1 Set value of Fine sync in PC signal Details (Available only in the normal Power ON status)
PDG-DWL100 Expand Serial Command Functional Specifications 8.6.4 CF_INPUT2 Command Command “CF_INPUT2_%1” [CR] “COMPUTERÿ ” ---------------------------- Select Computer1 Select Computer1 (Valid only when it is in the normal Power ON status.) Details The projector shows Image OSD at receiving the command. Acceptable “000”...
PDG-DWL100 Expand Serial Command Functional Specifications 8.6.9 CF_INPUT7 Command Command “CF_INPUT7_%1” [CR] “VIDEO” ---------------------------- Select Video Select Video (Valid only when it is in the normal Power ON status.) Details The projector shows Image OSD at receiving the command. Acceptable “000”...
PDG-DWL100 Expand Serial Command Functional Specifications Lamp Command 8.8.1 CF_LAMPH Command Command “CF_LAMPH_%1”[CR] “RST” Reset total lamp running time Details This command is available in normal Power ON status. Acceptable Acceptable Correspondence Unacceptable Unacceptable 8.8.2 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “ON”...
PDG-DWL100 Expand Serial Command Functional Specifications Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1” [CR] “000~010” “UP” --------------------------- Set Volume to UP “DN” --------------------------- Set Volume to DN Set value of Volume. (Valid only when in the normal Power ON status.) The command behaves the same as remote control, which adjusts volume directly and release the sound-mute function.
PDG-DWL100 Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_INPUTSEARCH Command Command “CF_INPUTSEARCH_%1” [CR] “ON” --------------------------- Set Input search to ON “OFF” ------------------------- Set Input search to OFF On/Off Input search. (Valid only when in the normal Power ON status.) The status set by this command is stored in EEPROM and the setting Details remains effective after the power is turned to ALL OFF status.
PDG-DWL100 Expand Serial Command Functional Specifications 8.10.4 CF_FDEFAULT Command Command “CF_FDEFAULT_%1” [CR] “RST” Return the settings to Factory Default status (Valid only when in the normal Details Power ON status) No display is shown when projector received command.. Acceptable “000” [CR] Correspondence Unacceptable “Error Code”...
PDG-DWL100 Expand Serial Command Functional Specifications 8.10.8 CF_ FANCONTROL Command Command “CFÿ ? FANCONTROLÿ ? %1” [CR] “ON” ------------------------------ Set On “OF” ------------------------------ Set Off Select Fan control. (Valid only when in the normal Power ON status.) The status set by this command is stored in EEPROM and the setting Details remains effective after the power is turned to ALL OFF status.
PDG-DWL100 Expand Serial Command Functional Specifications Status Read Command 9.1 Format PC issues a command in the format below: “CR_Command” [CR] Command: String When the projector receives the applicable command, it returns the required information as a data string. “000_” %1 [CR] %1: required Information (a data string.
PDG-DWL100 Expand Serial Command Functional Specifications 9.4 Image Status Read Commands 9.4.1 CR_BRIGHT Command Command “CR_BRIGHT” [CR] Details Get user controlled value of Brightness Acceptable “000_%1” [CR] Correspondence “-50” – “050” Unacceptable “?” [CR] 9.4.2 CR_CONT Command Command “CR_CONT” [CR] Details Get user controlled value of Contrast Acceptable...
PDG-DWL100 Expand Serial Command Functional Specifications 9.5 PC Status Read Commands 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] Correspondence "0000-0031" ------ Directly specify setting value of Fine sync “Error Code” [CR] -------------- When command is invalid in Unacceptable the given condition “?”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.5.5 CR_SETPCADJ Command Command “CR_SETPCADJ” [CR] Details Get value of Signal name. Acceptable “000_%1” [CR] This command is available only Input is PC-Analog. Get value of Signal name. “640x480”-----------------VGA1 is input. Correspondence “1024x768”----------------XGA1 is input “1600x1200”--------------UXGA1 is input Please tell us your spec about value of signal name.
PDG-DWL100 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get currently selected signal. Details Valid only when input is video. (Invalid when Slot is computer) Acceptable “000_%1” [CR] “1080i60”--------------- 1080i 60Hz “1080i50” -------------- 1080i 50Hz “1035i”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.7.3 CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Acceptable “000_%1” [CR] ”VGA1” ----------------------VGA1 is selected “VGA2” ----------------------VGA2 is selected “XGA1” ----------------------XGA1 is selected Slot is PC signal “1080i” ----------------------1080i is selected “1035i” ----------------------1035i is selected “720p”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Commands 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL”[CR] Details Get information of Lamp Replacement time Acceptable “000_%1”[CR] “1Y” -------------------------- Over lamp replacement time “1N” -------------------------- Within lamp replacement time “1” means the number of lamps. Response (1 lamp model→...
PDG-DWL100 Expand Serial Command Functional Specifications 9.9.5 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of projector (in hours) Acceptable “000_%1” [CR] Correspondence “0000000” – “0099999” Unacceptable “?” [CR] 9.9.6 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.11 Setting Status Read Commands 9.11.1 CR_INPUTSEARCH Command Command “CR_INPUTSEARCH” [CR] Details Get Input search setting status Acceptable “000_%1” [CR] “ON” ------------------- Input search is set to on. Correspondence “OFF” ----------------- Input search is set to off. Unacceptable “?”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.11.5 CR_PJLOCKNOW Command Command “CR_PJLOCKNOW” [CR] Details Get setting status of current PJ Lock status Acceptable “000_%1” [CR] “LOCK” ---------- Projector is locked and the password is needed to release the lock “FREE” ------------ Either of; 1) Security function is off 2) Correspondence Security function is on but the password have been entered and the projector has...
PDG-DWL100 Expand Serial Command Functional Specifications 9.11.10 CR_FANCONTROL Command Command “CR_FANCONTROL” [CR] Details Get setting status of Fan control. Acceptable “000_%1” [CR] “ON” -------------------- On is selected. Correspondence “OFF” ------------------- Off is selected. Unacceptable “?” [CR] 9.11.11 CR_LAMPLIFERE Command Command “CR_LAMPLIFERE”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command Command “CR_STATUS” [CR] Get status of Projector. Details This command is the same as “CR0” of Basic command, but it returns an error code. Acceptable “000_%1” [CR] “00”...
PDG-DWL100 Expand Serial Command Functional Specifications 9.12.5 CR_TEMPWARN Command Command “CR_TEMPWARN” [CR] Get the information about the temperature inside the projector (1) close to an abnormal status 2) in an abnormal status 3) temperature Details level is normal 4)abnormal status is not detected). Possible to get data from plural sensor s at once.
PDG-DWL100 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command “CR_TEMP” [CR] Get the information about the temperature inside the projector (1) close to the abnormal 2) in the abnormal status 3) in the safe Details temperature level 4)abnormal status is not detected). Possible to get data from plural sensor s at once.