PDG-DWL100 Expand Serial Command Functional Specifications

9.12.7 CR_TEMP Command

Command
"CR_TEMP" [CR]
Get the information about the temperature inside the projector
(1) close to the abnormal 2) in the abnormal status 3) in the safe
Details
temperature level 4)abnormal status is not detected).
Possible to get data from plural sensor s at once.
Acceptable
Correspondence
Unacceptable
"000_%1" [CR]
%1=Temperature of sensor1
%2=Temperature of sensor2
%1, %2----------------fixed 6 digits.
Between %1 and %2 is space 1 character.
"_31.5ÿ & "
"_" means a space and "_" changes into "-", when
temperature gets below freezing.
e.g. -05.5F
The last character shows if corresponding sensor is under
abnormal temperature.
"F" ------- Abnormal temperature
"W"-------Close to abnormal temperature(Temperature is as
high to display Warning)
"S" -------Not close to abnormal temperature (Temperature is
low enough and safe.)
"N"-------Applicable sensor does not detect abnormal
%1,%2,%3
temperature
"E" -------Not able to return temperature data
When several sensors are incorporated, projector returns
values continuously.
Etc. "_31.5F__35.2S"[CR]
A data of sensor 1 comes first and a data of sensor 2 follows
after single space.
As described respectively in e.g., sensor 1 detects abnormal
temp., sensor 2 detects 35.2 degrees which means safe
temperature.
.
In case projector cannot return its data due to some hard
ware failure, the last character becomes "E" such as
"_00.0E".
Some of the projectors get abnormal temperature because
of heat of Lamp ballast in Standby mode or Powering ON.
Therefore detection of abnormal temperature is suspended
while Standby mode or adequate time after Power ON, and
during that time projector returns "_----N" as a temperature
data.
"?" [CR]