PDG-DWL100 Expand Serial Command Functional Specifications
9.11
Setting Status Read Commands
9.11.1 CR_INPUTSEARCH Command
Command
"CR_INPUTSEARCH" [CR]
Details
Get Input search setting status
Acceptable
Correspondence
Unacceptable
9.11.2 CR_LANG Command
Command
"CR_LANG" [CR]
Details
Get selected language
Acceptable
Correspondence
Unacceptable
9.11.3 CR_P-MANETIME Command
Command
"CR_P-MANETIME" [CR]
Details
Get value of Power management timer
Acceptable
Correspondence
Unacceptable
9.11.4 CR_SECURITY Command
Command
"CR_SECURITY" [CR]
Details
Get status of Security setting.
Acceptable
Correspondence
Unacceptable
"000_%1" [CR]
"ON" ------------------- Input search is set to on.
%1
"OFF" ----------------- Input search is set to off.
"?" [CR]
"000_%1" [CR]
"ENG" -------------------------- English is selected
"DEU" -------------------------- German is selected
"FRA" -------------------------- French is selected
"ITA" ---------------------------- Italian is selected
"ESP" -------------------------- Spanish is selected
"SVE" -------------------------- Swedish is selected
"CHI" --------------------------- Chinese is selected
"JPN" --------------------------- Japanese is selected
%1
"POL" --------------------------- Pohland is selected
"TUR" --------------------------- Turkish is selected
"GRE" --------------------------- Greece is selected
"NOR" --------------------------- Norway is selected
"CZE" --------------------------- Czech is selected
"KOR" --------------------------- Korea is selected
"RUS" --------------------------- Russia is selected
"POR" --------------------------- Portuguese is selected
"HUN" --------------------------- Hungarian is selected
"?" [CR]
"000_%1" [CR]
%1
"000" – "180"
"?" [CR]
"000_%1" [CR]
"ON" ----------------------- On is selected in Security menu
%1
"OFF" --------------------- Off is selected in Security menu
"?" [CR]
42 / 47