Indicators

LCD
The Liquid Crystal Display (LCD) on the front of the WD Sentinel server is a portal
into its status. Normally, the LCD displays the name of the WD Sentinel server that
the administrator assigned during initial setup along with its IP address. You can use
either of these to discover and communicate with the server. (See the Quick Install
Guide for Administrators.)
Use the scroll buttons to the right of the LCD to display:
Number of drives that are installed
Available capacity
Status
If an alert occurs, or the WD Sentinel server is performing certain operations, the
status displays in the LCD:
Alert
Backup Failed
Capacity Low
Drive Overtemp
Ethernet 1 Disconnected
Ethernet 2 Disconnected
Fan Failed
Imminent Drive Failure
Initializing
Invalid Drive
Invalid Drive Capacity
Migrating ... %
Network Disconnected
Power Supply 1 Failed
Power Supply 2 Failed
Reboot
Repairing ... %
Shutting Down
WD SENTINEL DX4000
ADMINISTRATOR'S GUIDE
Description
The server failed to back up a computer. Go to the Dashboard
and examine the alerts to discover which computer backup failed.
Available storage capacity of the WD Sentinel server is low.
The temperature of one of the drives is too high.
WD Sentinel server has detected that Ethernet 1 has lost
connection.
WD Sentinel server has detected that Ethernet 2 has lost
connection.
WD Sentinel server has detected that the fan is no longer
operational.
One of the drives is demonstrating imminent failure (discovered
through Self-Monitoring Analysis and Reporting Technology
S.M.A.R.T). Replace the drive as soon as possible.
The RAID system is initializing the storage; this is similar to
Verifying.
A drive that is not approved for use in the WD Sentinel server has
been inserted.
A drive with incompatible size was inserted and migration/rebuild
could not proceed.
RAID system is migrating to a larger capacity due to the addition
of a drive.
The server is not connected to the network.
Power supply 1 has failed or been disconnected.
Power supply 2 has failed or been disconnected.
WD Sentinel server will reboot.
RAID system is being repaired to full RAID protection.
WD Sentinel server is shutting down.