Auto Configuration
EDO
DRAM Speed Selection : 60 ns
EDO CASx# MA Wait Srate
EDO RASx# Wait State
SDRAM RAS-to-CAS Delay
SDRAM RAS Precharge Time
SDRAM CAS latency Time
SDRAM Precharge Control
DRAM Data Integrity Mode
System BIOS Cacheable
Video BIOS Cacheable
Video RAM Cacheable
8 Bit I/O Recovery Time
16 Bit I/O Recovery Time
Memory Hole At 15M-16M
Passive Release
Delayed Transaction
AGP Aperture Size
Esc: Quit
F1 : Help
F5 : Old Values
• CPU HOST/PCI Clock: In this item you can choose the CPU HOST/PCI Clock. The setting are:
Default ,66/33,75/37,83/41,100/33,103/34, 112/37,124/41,133/44, 105/35,110/36,115/38,
120/40,124/31,133/33.
When the setting is :'default" the CPU HOST Clock will depend on the setting of JP14 and JP15.
If JP14,JP15 is set to 66MHz only have the choice of 66/33, 75/37, 83/41on screen.
If the JP14,JP15 is setting at 100MHz, then you can have 100/33,103/34,112/37,124/41, 133/44
105/35,110/36,115/38,120/40,133/33.
*Please turn off system power if the screen does not have any display after change of the setting.
Then press and hold down " INS " key, and turn on system power again (release " INS " key till
the screen has display) to reset correct frequency of CPU HOST clock.
• Core:+3.3V,+5V,+12V,-12V,are show the status of system voltages.

3-4 POWER MANAGEMENT SETUP

The Power Management Setup allows you to configure you system to most effectively save
energy while operating in a manner consistent with your own style of computer use.
: Enabled
: 2
: 1
: 3
: 3
: 3
: Disabled
: Non-ECC
: Enabled
: Enabled
: Disabled
: 1
: 1
: Disabled
: Enabled
: Disabled
: 64
↑↓→←: Select Ite m
Pu/Pd/+/-:Modify
(Shift)F2 : Color
Figure 3-3
ROM PCI/ISA BIOS (2A69KJ1L)
POWER MANAGEMENT SETUP
AWARD SOFTWARE, INC.
Auto Detect DIMM/PCI Clk : Enabled
Spread Spectrum Modulated: Disabled
CPU Host/PCI Clock
CPU
Warnung Temperature : Disabled
Current System Temp.
Temperature : 34 ° C/93 ° F
Current CPU
Current CPUFAN
Speed
Current SYSFAN Speed
Core : 2.80V
+3.3V
+5V
: 5.10V
+12V
-12V : 12 V
F6 : Load Optimal Defaults
F7 : Load Standard Defaults
21
: Default
: 44 ° C/111 ° F
: 0 RPM
: 0 RPM
: 3.3V
: 12 V

Advertisement