Release Lever - Pfaff 1295 Instruction Manual

Hide thumbs Also See for 1295:
Table of Contents

Advertisement

Adjustment
11

Release lever

.05.12
11 - 31
Requirement
When the pin of control lever 3 has dropped into the track of control cam 4 and the needle
bar is at b.d.c. there must be a clearance of about 1 mm between control lever 3 and
release lever 5. In this position the needle thread tension must still be engaged.
3
Fig. 11 - 29
Turn eccentric 1 (screw 2) according to Requirement
4
2
5
1