Needle-Thread Tension Release - Pfaff 1295 Instruction Manual

Hide thumbs Also See for 1295:
Table of Contents

Advertisement

Adjustment
11

Needle-thread tension release

.04.13
11 - 15
Requirement
With the lifting presser raised, there must be a clearance of at least 0.5 mm between
tension discs 4.
Fig. 11 - 13
Position pressure plate 1 behind mounting bracket 2 according to Requirement.
The clearance of 0.5 mm is a miminum setting and may be as much as 1 mm
for heavy threads.
When the tension is engaged, release pin 3 must not be under load.
1
3
2
0.5 mm
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1296

Table of Contents