Code
SC306
Charge grid high voltage error: M
SC307
Charge grid high voltage error: Y
SC308
Charge cleaning unit: Position error: K
SC309
Charge cleaning unit: Position error: C
SC310
Charge cleaning unit: Position error: M
SC311
Charge cleaning unit: Position error: Y
SC420
Potential sensor error: Vd Adjustment K
SC421
Potential sensor error: Vd Adjustment C
SC422
Potential sensor error: Vd Adjustment M
SC423
Potential sensor error: Vd Adjustment Y
SC424
Potential sensor error: Vl adjustment K
SC425
Potential sensor error: Vl adjustment C
SC426
Potential sensor error: Vl adjustment M
SC427
Potential sensor error: Vl adjustment Y
SC432
Potential sensor error 1: Vr adjustment K
SC433
Potential sensor error 2: Vr adjustment K
SC434
Potential sensor error 3: Vr adjustment M
SC435
Potential sensor error 4: Vr adjustment Y
SC450
PTR HVPS output error
SC460
Separation HV output error
Error
6
Procedure
Replace the magenta charge corona
unit.
Replace the yellow charge corona unit.
Detach and reattach the black charge
corona unit or replace it.
Detach and reattach the cyan charge
corona unit or replace it.
Detach and reattach the magenta
charge corona unit or replace it.
Detach and reattach the yellow charge
corona unit or replace it.
Replace the black drum unit.
Replace the cyan drum unit.
Replace the magenta drum unit.
Replace the yellow drum unit.
Replace the black drum unit.
Replace the cyan drum unit.
Replace the magenta drum unit.
Replace the yellow drum unit.
Replace the black drum unit.
Replace the cyan drum unit.
Replace the magenta drum unit.
Replace the yellow drum unit.
Detach and reattach the paper transfer
roller unit or replace it.
Detach and reattach the paper transfer
roller unit or replace it.