10. Rotate the [ Main Tuning Dial ] knob to tune around
the band, and begin normal operation.
Q Q Q Q Q
N N N N N
UICK
UICK
UICK
UICK
UICK
O O O O O TE
TE
TE
TE
TE
Clockwise rotation of the Main tuning Dial in-
creases the operating frequency, one "step" of the
synthesizer at a time; similarly, counter-clockwise
rotation of the [ Main Tuning Dial ] knob will
decrease the frequency.
Two steps, one "normal" and one "fast," are avail-
able on each operating mode. Pressing the
[ FAST ] key engages the "Fast" tuning selection.
Operating Mode
LSB, USB, CW, RTTY, 10 Hz [100 Hz] 10 kHz [100 kHz]
PKT(LSB)
AM, FM, PKT(FM)
[ ] : [ FAST ] switch set to "ON"
O
PERATION ON
The FT
9000D includes the capability for transmission and reception on the five spot frequencies assigned to the
DX
Amateur Service in the United States.
To operate on the 60-meter band channels:
Press the [ V/M ] switch to enter the Memory mode. A
1
memory channel number will appear in the multi-
panel window.
2. Press the [ MCH/GRP ] key momentarily.
The Red LED inside the switch will light up, indicat-
ing that you are ready to recall a memory channel.
A A A A A
D D D D D VICE
VICE
VICE
VICE
VICE
If the Red LED imbedded in the [ MCH/GRP ] switch
does not light up, check to be sure that the orange
lamp to the right of the [ CLAR/VFO-B ] knob is not
illuminated. It is, press the [ A/B ] switch to make it go
out, then press the [ MCH/GRP ] key again.
3. Rotate the [ CLAR/VFO-B ] knob to select the desired
60-meter band channel.
The 60-meter band channels are set to USB, and they
appear between the "last" PMS channel ("P9U") and
the first "regular" memory channel (Channel 1).
4. To exit from 60-meter operation and return to the VFO
mode, just press the [ V/M ] switch
FT
9000D O
DX
PERATION
B
O
ASIC
PERATION
1 Step
1 Dial Rotation
100 Hz [1 kHz] 100 kHz [1 MHz]
( 5 MH
60-M
ETER
M
ANUAL
: R
ECEIVING ON
It is possible to separate the frequency change
over one dial rotation, while operating solely on
the CW mode, using the Menu items "TUNING
139 DIAL STEP," and "TUNING 140 DIAL
CW FINE" See page 158.
If you want to navigate quickly, so as to effect
rapid frequency change, there are several tech-
niques available:
o Direct keyboard frequency entry of the fre-
quency (see page 58).
o Use the [ CLAR/VFO-B ] knob to tune in 1
MHz steps (see page 58).
o Use the microphone's Up/Down scanning
keys, if your microphone is so equipped.
) B
( U.S.
Z
AND
VERSION ONLY
[ V/M ] key
[ MCH/GRP ] key
Be sure to observe all current regulations regarding Ef-
fective Radiated Power (E.R.P.) while operating on the
60-meter band.
N N N N N
The frequencies and operating mode for 5 MHz
band operation are both fixed, and may not be
changed.
C
N
HANNEL
UMBER
US1
US2
US3
US4
US5
A
B
MATEUR
ANDS
)
[ CLAR/VFO-B ] knob
O O O O O TE
TE
TE
TE
TE
F
REQUENCY
5.3320 MHz
5,3480 MHz
5.3680 MHz
5.3730 MHz
5.4050 MHz
Page 45