123. MAIN FIX 18 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
17 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 18000 - 18199 kHz (1 kHz steps)
Default Setting: 18068 kHz
124. MAIN FIX 21 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
15 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 21000 - 21449 kHz (1 kHz steps)
Default Setting: 21000 kHz
125. MAIN FIX 24 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
12 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 24800 - 24989 kHz (1 kHz steps)
Default Setting: 24890 kHz
126. MAIN FIX 28 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
10 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 28000 - 29699 kHz (1 kHz steps)
Default Setting: 28000 kHz
127. MAIN FIX 50 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
6 m amateur band, when the optional Data Manage-
ment Unit (DMU-9000) and TFT Display Unit (TFT-
9000) are installed.
Available Values: 50000 - 53999 kHz (1 kHz steps)
Default Setting: 50000 kHz
FT
9000 C
O
DX
ONTEST
SCOPE G
M
PERATION
ANUAL
ROUP
128. SUB FIX 1.8 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
main band (VFO-A) 160 m amateur band, when the
optional Data Management Unit (DMU-9000) and
TFT Display Unit (TFT-9000) are installed.
Available Values: 1800 - 1999 kHz (1 kHz steps)
Default Setting: 1800 kHz
129. SUB FIX 3.5 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
80 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 3500 - 3999 kHz (1 kHz steps)
Default Setting: 3500 kHz
130. SUB FIX 5.0 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
60 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 5250 - 5499 kHz (1 kHz steps)
Default Setting: 5250 kHz
131. SUB FIX 7.0 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
40 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 7000 - 7299 kHz (1 kHz steps)
Default Setting: 7000 kHz
132. SUB FIX 10 MHz
Function: Selects the scan start frequency of the
FIX mode Spectrum Scope while monitoring on the
30 m amateur band, when the optional Data Man-
agement Unit (DMU-9000) and TFT Display Unit
(TFT-9000) are installed.
Available Values: 10100 - 10149 kHz (1 kHz steps)
Default Setting: 10100 kHz