  • Page 2: Serial Out

    PERATION OMPUTER IDED RANSCEIVER CAT J VERVIEW The CAT (Computer Aided Transceiver) System in the 9000 series provides control of frequency, VFO, memory, and other settings such as dual-channel memo- ries and diversity reception using an external personal computer. This allows multiple control operations to be fully automated as single mouse clicks or keystroke op- erations on the computer keyboard.
  • Page 3 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND Parameters A computer control command is composed of an alpha- betical command, various parameters, and the terminator Parameters are used to specify information necessary to that signals the end of the control command. implement the desired command. Example: Set the main band (VFO-A) frequency to The parameters to be used for each command are prede- 14.250000 MHz.
  • Page 4 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND OMMAND UNCTION OMMAND UNCTION VFO-A TO VFO-B MODE KEY ANTENNA TUNER CONTROL MONITOR LEVEL AF GAIN MEMORY READ AUTO INFORMATION METER SW AF LIMITER MEMORY WRITE VFO-A TO MEMORY CHANNEL MOX SET ANTENNA NUMBER NARROW VFO-B TO VFO-A NOISE BLANKER...
  • Page 5 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES VFO-A TO VFO-B Read Answer A A A A A C C C C C ANTENNA TUNER CONTROL P1 0: Fixed P3 0: Tuner “OFF” P2 0: Fixed 1: Tuner “ON” P1 P2 P3 2: Tuning Start Read Answer...
  • Page 6 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES BAND DOWN P1 0: Main (VFO-A) Band 1: Sub (VFO-B) Band Read Answer BREAK-IN P1 0: Break-in “OFF” 1: Break-in “ON” Read Answer MANUAL NOTCH P1 0: Main (VFO-A) Band Receiver P3 When P2=0 1: Sub (VFO-B) Band Receiver 000: OFF P1 P2 P3 P3 P3...
  • Page 7 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES CTCSS TONE FREQUENCY P1 0: Main (VFO-A) Band Receiver 1: Sub (VFO-B) Band Receiver P1 P2 P2 P2 0 - 49: Tone Frequency Number (See “CTCSS Tone Chart” Below) Read Answer P1 P2 P2 CONTOUR/APF P1 0: Main (VFO-A) Band Receiver P3 When P2=0,...
  • Page 8 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES ENCORDER DOWN P1 0: MAIN ENCORDER 1: SUB ENCORDER P1 P2 P2 P2 01-99: Steps Read Answer ENT KEY Read Answer ENCORDER UP P1 0: MAIN ENCORDER 1: SUB ENCORDER P1 P2 P2 P2 01-99: Steps Read Answer...
  • Page 9 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES ABLE FUNCTION BYTE TX TIME OUT TIMER 0: OFF 1: 5 min 2: 10 min 3: 15 min 4: 20 min 5: 25 min 6: 30 min TRANSVERTER FREQUENCY DISPLAY 30 ~ 49 MHz μ-TUNE DIAL STEP 0: STEP-2 1: STEP-1...
  • Page 10 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES ABLE FUNCTION BYTE SUB BAND SPECTRUM SCOPE SCAN START FREQ. ( 3.5 MHz ) 03500 ~ 03999 (3.500 MHz ~ 3.999 MHz) SUB BAND SPECTRUM SCOPE SCAN START FREQ. ( 5.0 MHz ) 05250 ~ 05499 (5.250 MHz ~ 5.499 MHz) SUB BAND SPECTRUM SCOPE SCAN START FREQ.
  • Page 11 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES F F F F F A A A A A FREQUENCY VFO-A P1 00300000 - 60000000 (Hz) P1 P1 P1 P1 P1 P1 P1 P1 Read Answer P1 P1 P1 P1 P1 P1 P1 P1 FREQUENCY VFO-B P1 00300000 - 60000000 (Hz) P1 P1 P1 P1 P1 P1 P1 P1...
  • Page 12: Command Tables

    PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES IF IF INFORMATION P1 000-117 (Memory Channel) P2 VFO-A Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Clarifier Offset: 0000 - 9999 (Hz) Read P4 0: RX CLAR “OFF” 1: RX CLAR “ON”...
  • Page 13 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES LOCK P1 0: DIAL Lock “OFF” 1: DIAL Lock “ON” Read Answer LOAD MESSEGE P1 0: DVS P2 When P1=0 When P1=1 1: P. B 0: DVS (Recording Stop) 0: P.B (Recording Stop) P1 P2 1: DVS (CH “1”...
  • Page 14 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES MEMORY CHANNEL READ P1 Memory Channel Number P2 Memory Channel Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Clarifier Offset: 0000 - 9999 (Hz) Read P4 0: RX CLAR “OFF” 1: RX CLAR “ON”...
  • Page 15 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES OPPOSITE BAND INFORMATION P1 Current Memory Channel P2 VFO-B Frequency (Hz) P3 Clarifier Direction +: Plus Shift, -- : Minus Shift Crarifier Offset: 0000 - 9999 (Hz) Read P4 0: RX CLAR “OFF” 1: RX CLAR “ON”...
  • Page 16 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES QMB STORE Read Answer QMB RECALL Read Answer QUICK SPLIT Read Answer RF ATTENUATOR P1 0: Main (VFO-A) Band Receiver P2 0: OFF 1: Sub (VFO-B) Band Receiver 1: 3 dB P1 P2 2: 6 dB Read 3: 12 dB...
  • Page 17 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES NOISE REDUCTION LEVEL P1 0: Main (VFO-A) Band Receiver 1: Sub (VFO-B) Band Receiver P1 P2 P2 Read P2 01 - 15 Answer P1 P2 P2 READ METER P1 00: Current Main Meter 04: S Meter (Main) 11: VDD Meter 01: Current Sub Meter...
  • Page 18 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES WIDTH P1 0: Main (VFO-A) Band Receiver 1: Sub (VFO-B) Band Receiver P1 P2 P2 Read P2 00 (Counter Clockwise) - 31 (Clockwise), 16 (Center) Answer P1 P2 P2 S-METER READING P1 0: Main (VFO-A) Band S-meter 1: Sub (VFO-B) Band S-meter P2 000 - 255 Read...
  • Page 19 PERATION OMPUTER IDED RANSCEIVER ONTROL OMMAND ABLES VRF FILTER P1 0: Main (VFO-A) Band Receiver P3 +: Plus Shift 1: Sub (VFO-B) Band Receiver –: Minus Shift P1 P2 P3 P4 Read P2 0: OFF P4 0 - 9 (Step) 1: ON P5 000 - 255 2: Default set...
  • Page 20 PERATION OMPUTER IDED RANSCEIVER Copyright 2008 VERTEX STANDARD CO., LTD. All rights reserved No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. 9000 S CAT O ERIES PERATION EFERENCE...