Menu Mode Setting - Yaesu FT DX 9000 CONTEST Operation Manual

Hide thumbs Also See for FT DX 9000 CONTEST:
Table of Contents

Advertisement

001. MAIN-FAST-DELAY
Function: Sets the delay time for the AGC FAST
mode of the main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
002. MAIN-FAST-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC FAST mode of the main band (VFO-
A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
003.MAIN-MID-DELAY
Function: Sets the delay time for the AGC MID mode
of the main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
004. MAIN-MID-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC MID mode of the main band (VFO-
A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
005. MAIN-SLOW-DELAY
Function: Sets the delay time for the AGC SLOW
mode of the main band (VFO-A) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 2000 msec
006. MAIN-SLOW-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC SLOW mode of the main band (VFO-
A) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
FT
9000 C
O
DX
ONTEST
AGC G
M
PERATION
ANUAL
ROUP
007. SUB-FAST-DELAY
Function: Sets the delay time for the AGC FAST
mode of the sub band (VFO-B) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
E
: When the Dual Receive Unit (RXU-
XPLANATION
9000) is installed, once the input signal falls below
the AGC threshold, it is possible to configure the AGC
decay time in 20 ms steps.
A
: If the Dual Receiver Unit (RXU-9000) is not
DVICE
installed, changing this setting will have no effect.
008. SUB-FAST-HOLD
Function: Sets the hang time of the AGC peak volt-
age for the AGC FAST mode of the sub band (VFO-
B) receiver.
Available Values: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
E
: When the Dual Receive Unit (RXU-
XPLANATION
9000) is installed, once the input signal falls below
the AGC threshold, it is possible to configure the AGC
decay time in 20 ms steps.
A
: If the Dual Receiver Unit (RXU-9000) is not
DVICE
installed, changing this setting will have no effect.
009. SUB-MID-DELAY
Function: Sets the delay time for the AGC MID mode
of the sub band (VFO-B) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
E
: When the Dual Receive Unit (RXU-
XPLANATION
9000) is installed, once the input signal falls below
the AGC threshold, it is possible to configure the AGC
decay time in 20 ms steps.
A
: If the Dual Receiver Unit (RXU-9000) is not
DVICE
installed, changing this setting will have no effect.
M M M M M
M M M M M
ENU
ENU
ENU
ODE
ODE
ODE
ENU
ENU
ODE
ODE
Page 131

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftdx9000 contest

Table of Contents