Simrad ER60 - REV B Operator's Manual page 99

Scientific echo sounder application
Table of Contents

Advertisement

850-164692 / Rev.B
Pelagic - The range settings for the layer are referenced to the
surface. The layer is not downwards limited by the detected
bottom depth.
Bottom - The range settings for the layer are referenced to the
bottom. The layer is downwards limited by the detected bottom
depth.
Integration
Targets Integration - Check the Targets Integration box to
calculate integration values based on single target detections.
Compared with the normal integration (sA) this value can be
used to get an idea of how much of the biomass has been
detected as single targets.
Margin - This is the margin to the surface and the bottom used
when calculating integration values for Surface and Bottom
types.
Sv threshold - This is the lower threshold used when
calculating integration values for the layer.