Installation Manual
H3C S7500 Series Ethernet Switches
Step 2: Set the parameters for Windows XP HyperTerminal as follows:
Bits per second: 9600
Data bits: 8.
Parity check: None
Stop bits: 1
Flow control: None
Terminal emulation: VT100
The parameter setting procedure is as follows:
1)
Select Start > Programs/All Programs > Accessories > Communications >
HyperTerminal to enter the HyperTerminal window to establish a new connection
and the system displays the Connection Description dialog box.
Figure 5-2 Connection description of HyperTerminal
2)
Enter the name of the new connection in the Connection Description dialog box
and click OK. Then the system displays the Connect To dialog box.
3)
Select the serial port to which the cable is connected from Connect using
dropdown list.
Chapter 5 System Commissioning
5-2