Configuring the System Fan

The minitower system can be configured for a 2-wire or 3-wire fan by
jumpering block JP3 as follows:
2-wire fan, pins 1-2 jumpered (the default)
!
3-wire fan, pins 2-3 jumpered.
!

Hard Drive Jumper Settings

Hard drive jumpering varies according to the particular model in the
system and how that model is configured. The following subsections
provide jumper settings for Seagate Barracuda, and Quantum Viking
drives.

Seagate Barracuda

The Seagate Barracuda SCSI drive uses jumper blocks
A3, A2, A1, and A0 to configure the SCSI ID for the drive. See the
documentation that comes with the drive for more information on when to
configure the drive. The SCSI ID jumpering is listed below.
!
SCSI ID=0, no jumpers
SCSI ID=1, A0 jumpered
!
SCSI ID=2, A1 jumpered
!
SCSI ID=3, A1 and A0 jumpered
!
SCSI ID=4, A2 jumpered
!
SCSI ID=5, A2 and A0 jumpered
!
SCSI ID=6, A2 and A1 jumpered
!
SCSI ID=7, A2, A1, and A0 jumpered
!
SCSI ID=8, A3 jumpered
!
SCSI ID=9, A3 and A0 jumpered
!
SCSI ID=10, A3 and A1 jumpered
!
SCSI ID=11, A3, A1, and A0 jumpered
!
SCSI ID=12, A3 and A2 jumpered
!
SCSI ID=13, A3, A2, and A0 jumpered
!
SCSI ID=14, A3, A2, and A1 jumpered
!
SCSI ID=15, A3, A2, A1, and A0 jumpered
!
Configuring the System 3-53