Removing The Plastic Fan Guide; Replacing The Plastic Fan Guide; Cooling Shrouds; System Board Cooling Shroud - Dell POWEREDGE 1950 Hardware Owner's Manual

Dell computer hardware user manual
Hide thumbs Also See for POWEREDGE 1950:
Table of Contents

Advertisement

Removing the Plastic Fan Guide

NOTE:
The plastic fan guide is mounted to the chassis between the fans.
NOTE:
You may need to remove the system from the rack.
1 Remove the cooling fan modules. See "Removing a Cooling Fan Module" on page 48.
2 Remove the system from the rack. See the Rack Installation Guide for your system.
3 Place the system upside-down on a flat surface.
4 Using a #2 Phillips screwdriver, remove the two screws from the bottom of the chassis that secure the fan
bracket.
5 Turn the system right-side up, place it on a flat surface, and then remove the fan bracket.

Replacing the Plastic Fan Guide

1 While the system is out of the rack, and with the top cover removed, place the system on its side on a flat
surface.
2 Place the fan bracket into its location inside the chassis.
3 Holding the fan bracket in place, use a #2 Phillips screwdriver to replace the two screws on the bottom of
the chassis.
4 Place the system right-side up on a flat surface.
5 Replace the cooling fan modules. See "Replacing a Cooling Fan Module" on page 49.
6 Replace the system in the rack. See the Rack Installation Guide for your system.

Cooling Shrouds

Your system contains two cooling shrouds.

System board cooling shroud

Memory cooling shroud
System Board Cooling Shroud
The system board cooling shroud directs airflow over the system memory modules, channeling the air from the
four fan modules. See Figure 3-5.