ZyAIR G-5100 User's Guide
Figure 119 Inspection Cosmetic and Function
TEST ITEM
High
Temperature
Operation
Low
Temperature
Operation
High
Temperature
Storage
Low
Temperature
Storage
High
Temperature
High
Humidity
Temperature
Recycle
ESD
Approvals
Table 78 Approvals
SAFETY
199
TEST
CONDITION
Temp.
+70 Deg. C
Storage
24 hours
Test
Operation mode in the chamber
Spec.
The same as +25 Deg. C
Temp.
-20 Deg. C
Storage
24 hours
Test
Operation mode in the chamber
Spec.
The same as +25 Deg. C
Temp.
+80 Deg. C2
Storage
4 hours
Test
Operation mode in room temperature 4 hours
after the storage
Spec.
The same as +25 Deg. C
Temp.
-40 Deg. C
Storage
24 hours
Test:
Operation mode in room temperature 4 hours
after the storage
Spec.
The same as +25 Deg. C
Temp.
+40 Deg. C
Humidity
95%RH (non-condensing) 72 hours
Storage Test
Operation mode in room temperature 4
hours after the storage
Spec.
The same as +25 Deg. C
Temp. Cycle
+20->0->-20->0->+20->40->+60->+40->+20
Test
Operation in the chamber 1 hour after arriving
at the test temperature
Discharge By
±15KV (Each polarity 10 times)
Air
±8KV (Each polarity 10 times)
Discharge By
Contact
North America
European Union (CE mark)
CRITERIA
No Damage In
Cosmetics or Error In
Function
No Damage In
Cosmetics or Error In
Function
No Damage In
Cosmetics or Error In
Function
No Damage In
Cosmetics or Error In
Function
No Damage In
Cosmetics or Error In
Function
No Damage On
Electrical or Error In
Function
No Damage On
Electrical Performance
ANSI/UL-1950 3rdCSA C22.2 No. 950
3rd
EN60950
(1992+A1+A2+A3+A4+A11)IEC 60950
3rd
Appendix A Specifications