Using Cli Commands To Monitor Your Environment; System Alarms - Cisco 4500M Software Manual

Software guide
Table of Contents

Advertisement

Understanding Environmental Monitoring

Using CLI Commands to Monitor your Environment

Use the show environment CLI command to monitor the system. This section gives a basic overview of
the command and keywords you will need.
Enter the show environment [alarm | status | temperature] command to display system status
information. Keyword descriptions are listed in
Table 7-1
Keyword
alarm
status
temperature
The following example shows how to display the environment conditions. This output indicates that the
power supplies are different. The switch will use only one power supply and disable the other.
Switch# show environment
no alarm
Chassis Temperature
Chassis Over Temperature Threshold
Chassis Critical Temperature Threshold = 95 degrees Celsius
Power
Supply
------
PS1
PS2
*** Power Supplies of different types have been detected***
Switch#

System Alarms

The system has two types of alarms: major and minor. A major alarm indicates a critical problem that
could lead to system shutdown. A minor alarm is informational—it alerts you to a problem that could
turn critical if corrective action is not taken.
When the system issues an alarm (major or minor) that indicates an over-temperature condition, the
switch does not cancel the alarm nor take any action (such as module reset or shutdown) for five minutes.
If the temperature falls 5 degrees Celsius below the alarm threshold during this period, the alarm is
canceled.
An LED on the supervisor indicates if an alarm has been issued. See
Refer to the Catalyst 4500 Series Switch Module Installation Guide for information on LEDs, including
Note
the startup behavior of the supervisor engine system LED.
Software Configuration Guide—Release 12.2(25)EW
7-2
show environment Keyword Descriptions
Purpose
Displays environmental alarms for the system.
Displays field-replaceable unit (FRU) operational status and power
and power supply fan sensor information.
Displays temperature of the chassis.
Model No
Type
----------------
---------
PWR-C45-2800AC
AC 2800W
PWR-C45-1000AC
AC 1000W
Chapter 7
Environmental Monitoring and Power Management
Table
7-1.
= 35 degrees Celsius
= 75 degrees Celsius
Fan
Inline
Status
Sensor
Status
-----------
------
------
good
good
good
err-disable
good
n.a.
Table 7-2
for more information.
OL-6696-01