Chapter 7
Environmental Monitoring and Power Management
To configure combined mode on your Catalyst 4500 series switch, perform this task:
Command
Step 1
Switch# configure terminal
Step 2
Switch(config)# power redundancy-mode combined
Step 3
Switch(config)# end
Step 4
Switch# show power supplies
The power redundancy-mode combined command does not work on a Catalyst 4006 switch.
Note
The following example shows how to set the power management mode to combined mode.
Switch (config)# power redundancy-mode combined
Switch (config)# end
Switch#
The following example shows how to display the current power redundancy mode. The power supplies
needed by system: 2 indicates that the switch is in combined mode.
Switch# show power supplies
Power supplies needed by system :2
Switch#
Available Power for Catalyst 4500 Series Switches Power Supplies
Table 7-3
When your switch is configured to combined mode, the total available power in not the mathematical
sum of the individual power supplies. The power supplies have a sharing ratio predetermined by the
hardware. In combined mode, the total power available is P + (P * sharing-ratio), where P is the amount
of power in the power supply.
OL-6696-01
For variable power supplies, choose a power supply that provides enough power so that the chassis
and PoE requirements are less than the maximum available power. Variable power supplies
automatically adjust the power resources at startup to accommodate the chassis and PoE
requirements.
The 1400 W DC power supply does not support combined mode. If you set the power budget to 2,
the switch disregards this setting.
If you have the power management mode set to combined mode and only one power supply installed,
your switch will accept the configuration, but power is available from only one power supply.
When your switch is configured to combined mode, the total available power is not the mathematical
sum of the individual power supplies. The power supplies have a predetermined current sharing ratio
(See
Table 7-3 on page 7-10
The maximum available power for chassis and PoE for each power supply are listed in
page
7-10.
lists the power available for use in the various Catalyst 4500 series switches power supplies.
for more information.)
Purpose
Enters configuration mode.
Sets the power management mode to
combined mode.
Exits configuration mode.
Verifies the power redundancy mode for
the switch.
Software Configuration Guide—Release 12.2(25)EW
Power Management
Table 7-3 on
7-9