The communications settings of the hosts of the serial port A and B will be changed as
follows.
Before Conversion
Host Type
Protocol
Port Name
Comm. Speed (Host Link)
Data Bits (Host Link)
Stop Bits (Host Link)
Parity (Host Link)
Comm. Speed (1:N NT Link)
Unit No. (1:N NT Link)
N
o
t
e
N
o
t
e
N
o
t
e
The project data will be changed if you specify to convert the model to one of the following models
(if the project to be converted is a version lower than the one given in the following table).
NS model to be converted
NS15
NS5- @@ 1 @ -V2
NSJ5- @@ 1 @
NSH5- @@ 1 @ -V2
After the conversion, check the communications settings and make changes according to the
operating environment. For details on communications settings, refer to information on setting the
system and projects in the online help for the CX-Designer.
When the model is converted to an NS-series PT, the document table settings will be cleared, but
the set PDF files will not be deleted. The PDF files will remain in the project folder and other
specified folders. Delete the PDF files manually if they are not required.
Refer to 4-5 Macros for information on macros for NS-Runtime.
The model conversion will stop if there are items that cannot be converted to the NS-series PT. If
this occurs, the items that cannot be converted will be displayed in the Output Window. Check the
details, revise the project data so that it can be converted, and then attempt to perform model
conversion again.
Model after
conversion
Base screens will be resized to 800 x 600 dots.
Base screens will be resized to 640 x 480 dots.
Base screens will be resized to 640 x 480 dots.
Base screens will be resized to 320 x 240 dots.
Base screens will be resized to 320 x 240 dots.
SYSMAC-CS1/SYSMAC-CJ1/
SYSMAC-CV/SYSMAC-CJ2
Host Link
Toolbus
COM port
19,200
38,400, 57,600, or 115,200
4 bits, 5 bits, 6 bits, 7 bits, 8 or bits
1 bit/ 2 bits
Even, Odd, None, Mark, or Space
---
---
Project data version after conversion
Ver. 8.1
Ver. 8.0
Ver. 8.0
Ver. 8.0
3-5 Converting Projects
Screen Size
After Conversion
SYSMAC-PLC
Host Link
1:N NT Link
---
19,200
9600
7 bits (fixed)
2 bits (fixed)
Even (fixed)
High speed
0
3-17