Error message - Decoding failure
Not transmit an error message (Factory default setting)
Setting for the number of reading digits
When the number of reading digits is fixed, all codes having other lengths than that
specified can be rejected. Up to two reading digits can be set.
This setting is effective for codes such as Interleaved 2 of 5 for which security against
partial reading is insufficient.
While the number of reading digits to be fixed can be set by reading the code, the
number of reading digits cannot be set with a command since a code of the necessary
length must be read.
• To read codes of a known length, it is recommended that the number of digits be fixed.
• While the number of reading digits to be fixed can be set by reading the code, it is not affected by a
detail setting (p.63) for reading codes, including "Transfer ST/SP", "Not transfer ST/SP", "Transfer C/
D" and "Not transfer C/D".
• Fixing the number of reading digits does not affect WPC (JAN/EAN/UPC) or other fixed-length codes
and DataMatrix or other 2D codes.
E.g.: The following describes the steps for fixing the number of reading digits.
Read the second code of the necessary length
Fixed number of digits OFF for all codes (Factory default setting)
Fixed number of digits ON for all codes
Menu sheet
_TI_
_TG_
Setting start (ZZ)
Fixed number of digits ON (H1)
Read the first code of the necessary length
Setting end (ZZ)
Menu sheet
_H0_
_H1_
Section 4
Setting Method
Command
TI
TG
Command
H0
None
V400-R1CF/R1CS
User's Manual
73