Specifications
General specification
Applicable
Bar code
codes
2D code
Number of reading digits No upper limit (depends on bar width and reading distance)
Reading
Light source
performance (*)
Aiming light
Minimum resolution
Image capture device
Working distance (WD)
Field of view
Skew angle
Pitch angle
Tilt angle
Reading of bar codes on
curved surfaces
Interface
Communication
specification
OK/NG outputs
Function setting
Menu sheet reading method or host command method
method
Functional
Reading trigger
specifications
OK/NG signals
Indication LED
Buzzer
Power supply
Power voltage
specification
Consumption current
Environmental
Ambient temperature
specifications
Ambient humidity
Ambient atmosphere
Ambient light resistance 10,000 lx (fluorescent lamp), 100,000 lx (sunlight)
Vibration resistance
Degree of
IP54 (IEC60529)
protection
V400-R1CF/R1CS
100
User's Manual
JAN/EAN/UPC (A, E), CODE39, NW-7, ITF
Industrial2of5, CODE93, CODE128 (including EAN128), RSS
DataMatrix (ECC200), QR Code, Micro QR Code, PDF417, RSS
Four red LEDs (wave length: 630 nm)
Two green LEDs (wave length: 527 nm)
0.1 mm (bar code), 0.169 mm (2D code)
CMOS area sensor (1280 (H) x 1024 (V))
60 mm
52 x 41 mm (for WD = 60 mm)
-50 to 0°, 0 to +50°
-50 to 0°, 0 to +50°
360°
R > 15 mm (JAN8), R > 20 mm (JAN13)
RS-232C
NPN open collector output
External trigger (Transistor input)
Trigger by command (RS-232C)
Trigger a test reading by pressing the SCAN button on the product
OK signal is turned on to indicate a successful read
OK signal is turned on to indicate a successful read of registered label
NG signal is turned on to indicate a successful read of a non-registered
label
OK LED (green) illuminates to indicate a successful read
NG LED (red) illuminates for failed reading with an error message
output
Notifies a successful reading with a buzzer sound (Muting available)
4.5 to 5.5 VDC
During operation: 500 mA or less; during standby: 300 mA or less
At operation: 0 to + 45°C; At storage: 2 to + 60°C
At operation and storage: 20 to 85% RH (with no icing or condensation)
No corrosive gases
12 to 100 Hz, 19.6 m/s
(2G), 1 hour each in three directions
2