Echo-back Test
3-9
Echo-back Test
Command
Response
1. Test Data
2. Response Codes
28
This command performs an echo-back test.
MRC
SRC
Test Data
"08"
"01"
2
2
0 to 200
Response code
MRC
SRC
"08"
"01"
2
2
4
The test data can contain up to 200 (00C8H) bytes.
Set the test data within the following ranges according to the communications
data length setting.
Data length
7 bits
ASCII 20H to 7EH
8 bits
ASCII 20H to 7EH or A1H to FEH
Response code
"1001"
Command length too long
"2203"
Operation error
"0000"
Normal end
Example:
Command: [STX]010000801123[ETX][BCC]
Response: [STX]01000008010000123[ETX][BCC]
Test Data
0 to 200
Test data
Error name
The command is too long.
An error occurred in nonvola-
tile memory.
Processing was completed
normally.
Section 3-9
Cause