Omron G3ZA - MANUAL 2 User Manual page 82

Multi-channel power controller
Hide thumbs Also See for G3ZA - MANUAL 2:
Table of Contents

Advertisement

Status Lists
Use the status listed in the following tables to check G3ZA status.
Status
Bit
31 to 13
Not used.
12
Start/stop
11
Not used.
10
Not used.
9
Alarm output (applies to all channels)
8
Control output
7
Not used.
6
Not used.
5
Communications error (applies to all channels)
4
Zero cross error (applies to all channels)
3
Not used.
2
Heater overcurrent
1
SSR short-circuit
0
Heater burnout
Example:
Condition
Alarm output and zero cross error bit are ON.
Stopped with no errors
Status
H'00000210
H'00001000
OFF
ON
OFF
---
Operating
Stopped
OFF
---
OFF
---
OFF
ON
OFF
ON
OFF
---
OFF
---
No
Yes
No
Yes
OFF
---
No
Yes
No
Yes
No
Yes
Status
Appendix
Operating
Output
Error
65