Parameter List
If variables without parentheses are used in communications, the set values will be eight-digit (double-word)
data. If variables with parentheses are used in communications, the set values will be four-digit (word) data.
Example:
Variable type C4: Double word (8 digits)
Variable type 84: Word (4 digits)
Parameter List for Pre-V2 Controllers
Note Refer to Parameter List for V2 Controllers on page 69 for parameters for upgraded Controllers.
Level
Variable
Address
type
Opera-
C0 (80)
0000
tion
0001
0002
0003
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
000E
000F
0010
0011
0012
0013
0014
0015
0016
0017
0018
C1 (81)
0000
0001
0002
0003
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
66
Parameter
Version
---
CH1 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH2 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH3 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH4 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH5 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH6 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH7 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH8 control variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH1 status
---
CH2 status
---
CH3 status
---
CH4 status
---
CH5 status
---
CH6 status
---
CH7 status
---
CH8 status
---
CH1 heater ON current
H'00000000 to H'00000037 (0 to 55)
CH2 heater ON current
H'00000000 to H'00000037 (0 to 55)
CH3 heater ON current
H'00000000 to H'00000037 (0 to 55)
CH4 heater ON current
H'00000000 to H'00000037 (0 to 55)
CH1 heater OFF current
H'00000000 to H'00000037 (0 to 55)
CH2 heater OFF current
H'00000000 to H'00000037 (0 to 55)
CH3 heater OFF current
H'00000000 to H'00000037 (0 to 55)
CH4 heater OFF current
H'00000000 to H'00000037 (0 to 55)
CH1 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH2 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH3 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH4 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH5 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH6 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH7 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH8 manipulated variable
H'00000000 to H'000003E8 (0.0 to 100.0)
CH1 slope
H'00000000 to H'00000FA0 (0.0 to 400.0)
CH2 slope
H'00000000 to H'00000FA0 (0.0 to 400.0)
CH3 slope
H'00000000 to H'00000FA0 (0.0 to 400.0)
CH4 slope
H'00000000 to H'00000FA0 (0.0 to 400.0)
CH5 slope
H'00000000 to H'00000FA0 (0.0 to 400.0)
CH6 slope
H'00000000 to H'00000FA0 (0.0 to 400.0)
Setting/monitor range
Appendix
Default
Unit
---
---
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
---
---
---
---
---
---
---
---
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0
A
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
0.0
%
100.0
%
100.0
%
100.0
%
100.0
%
100.0
%
100.0
%

Advertisement