Characteristics
Measurement accuracy (see note)
Hysteresis
Cooling coefficient
Proportional band
Integral (reset) time
Derivative (rate) time
Control period
Sampling period
Dead band/overlap band
Alarm output setting range
Fuzzy strength
Fuzzy scale 1
Fuzzy scale 2
Set value backup
Set value backup period
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Dimensions
Degree of protection
Weight
EMC
Approved standards
Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400 C or 750 F max. is not guaranteed. The following
measurement accuracy values are applied to the E5ZE.
K and T at 100 C max. and U:
K and T at 100 F max. and U:
R, S, and W at 200 C max., and B at 1,000 C max.:
R, S, and W at 400 F max., and B at 1,800 F max.:
2. The measurement accuracy of the E5ZE used with any thermocouple is 1 C/ F. The thermocouple can be used under the following
temperature ranges to increase the measurement accuracy to as high as 0.1 C/ F.
K thermocouple:
T or U thermocouple:
N thermocouple:
J, E, L, or PLII thermocouple:
3. To ensure EMC conformance, refer to Wiring for Conformance to the EMC Directives on page 16.
6
Multipoint Temperature Controller
Thermocouple:
( 0.3% of the process value or 2 C, whichever greater) 1 digit max.
( 0.3% of the process value or 3.6 F, whichever greater) 1 digit max.
Platinum resistance thermometer:
( 0.3% of the process value or 0.8 C, whichever greater) 1 digit max.
( 0.3% of the process value or 1.5 F, whichever greater) 1 digit max.
0.0 C/ F to 99.9 C/ F for ON/OFF control only (in units of 0.1 C/ F)
0.0 to 10.0 (in units of 0.1)
0.0 C/ F to 999.9 C/ F (in units of 0.1 C/ F)
Cooling side: Cooling coefficient x Proportional band
0 to 3,999 s (in units of 1 s) (for both heating and cooling)
0 to 3,999 s (in units of 1 s) (for both heating and cooling)
Heating side: 1 to 99 s (in units of 1 s)
Cooling side: 1 to 99 s (in units of 1 s)
Approx. 200 ms for 8 control points
999 C/ F to 999 C/ F (in units of 1 C/ F)
999 C/ F to 9999 C/ F, 0 to 9999 C/ F (upper- and lower-limit alarm) (in units of 1 C/ F)
999.9 C/ F to 9999.9 C/ F, 0.0 to 9999.9 C/ F (upper- and lower-limit alarm) (in units of 0.1 C/ F)
0% to 99% (in units of 1%)
0.2 C/ F to 999.9 C/ F (in units of 0.1 C/ F)
0.02 C/s or F/s to 99.99 C/s or F/s (in units of 0.01 C/s or F/s)
Lithium battery
10 years min. at room temperature
20 M
min. between the FG terminal and all analog input terminals (at 500 VDC)
A leakage current of 1 mA AC max. with 500 VAC for 1 minutes between the FG terminal and all analog
input terminals
Malfunction: 10 to 55 Hz, 10 m/s
Destruction: 10 to 55 Hz, 20 m/s
2
Malfunction: 150 m/s
(15.3G), 3 times each in 6 directions
2
Destruction: 200 m/s
(20.4G), 3 times each in 6 directions
Operating:
10 C to 55 C (with no icing or condensation)
Storage:
25 C to 65 C (with no icing or condensation)
Operating:
35% to 85%
Storage:
35% to 95%
Without casing: 169.5 x 192 x 58 mm max.
With casing:
173.5 x 200 x 65 mm max.
IP00
Without casing: 900 g max.
With casing:
1,700 g max.
Emission Enclosure:
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance: ENV50141:
Immunity Burst:
Conforms to EN50081-2, EN50082-2 (see note 3)
3 C 1 digit max.
5.4 F 1 digit max.
4 C 1 digit max.
7.2 F 1 digit max.
0.0 C to 1,300.0 C, 0.0 F to 2,300.0 F
0.0 C to 400.0 C, 0.0 F to 700.0 F
400.0 C to 1,300.0 C, 700.0 F to 2,300.0 F
Any temperature
E5ZE
2
(1G) for 10 min each in X, Y, and Z directions
2
(2G) for 2 hrs each in X, Y, and Z directions
EN55011 Group 1 class A
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
ENV50140:
10 V/m (amplitude modulated, 80 MHz to 1 GHz)
(level 3)
10 V/m (pulse modulated, 900 MHz)
10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4: 2 kV power-line (level 3)