3-1-3

Test Output Parameters

Parameter name
S Test Output Mode
Fault Action
I/O Comment
Maintenance
Counter Mode
Choice
Threshold Mainte-
nance Counter
3-1-4

Safety Output Parameters

Parameter name
S Safety Output Chan-
nel Mode
S Dual Channel Safe-
ty Output Mode
I/O Comment
Maintenance
Counter Mode
Choice
Threshold Mainte-
nance Counter
44
Value
Description
Not Used
The corresponding test output is not used.
Standard Output
Specifies connecting to the input for a muting
lamp or PLC. Used as a monitor output.
Pulse Test Output
Specifies connecting a device with a contact
output in combination with the safety input.
Power Supply Out-
Specifies connecting to the power supply ter-
put
minal of a safety sensor. The voltage supplied
from the test output to the I/O power supply
(V, G) is output.
Muting Lamp Output
Specifies a muting lamp output. When the out-
(Terminal T3 only)
put is ON, disconnection of the muting lamp
can be detected.
Clear OFF
Sets the output state of the test output when a
communications error occurs.This parameter
Hold Last Data
is enabled when the Test Output Channel
Mode is set to Standard Output or Muting
Lamp Output.
32 characters max. Sets an I/O comment for the test output. The
I/O comment set here is used as the I/O tag in
the Logic Editor.
Time
Sets the operating mode for the maintenance
counter.
Count
0 to 4,294,967,295
Sets the threshold value for the maintenance
hours
counter.
Value
Description
Not Used
The safety output is not used. (External output
device not connected.)
Safety
Specifies not outputting the test pulse when
the output is ON. Contact between the output
signal line and the power supply (positive)
when the output is OFF and ground faults can
be detected.
Safety Pulse Test
Outputs the test pulse when the output is ON.
(Can be set the
Contact between the output signal line and
DST1-MD16SL-1
the power supply, and short circuits with other
only.)
output signal lines can be detected.
Single Channel
Specifies using Single Channel Mode. When
Single Channel is set, the safety output that
would be paired for the dual channel parame-
ter is also set to Single Channel Mode.
Dual Channel
Specifies using Dual Channel Mode. When
both of the safety outputs to be paired are nor-
mal, the outputs can be turned ON.
32 characters max. Sets an I/O comment for the safety output.
The I/O comment set here is used as the I/O
tag in the Logic Editor.
Time
Sets the operating mode for the maintenance
counter.
Count
0 to 4,294,967,295
Sets the threshold value for the maintenance
hours
counter.
Default
Not Used
Clear OFF
None
Time
0
Default
Not Used
Dual
Channel
None
Time
0
Section 3: Configuration