Omron CP1L - 12-2007 Operation Manual page 332

Cp1l cpu unit
Table of Contents

Advertisement

Inverter Positioning
Parameter
No.
n003
RUN command selection
n004
Frequency reference selection
n005
Stopping method selection
n006
Reverse rotation-prohibit
selection
n011
Maximum frequency (FMAX)
n016
Minimum output frequency
(FMIN)
n018
Acceleration/deceleration time
setting unit
n019
Acceleration time 1
n020
Deceleration time 1
n151
RS-422A/485 communications
timeover detection selection
(The time between receiving
PLC signals is monitored, Tim-
eout time: 2 s.)
n152
RS-422A/485 communications
frequency reference/display
unit selection
Example settings of 3G3MV parameters are listed below. Refer to the User's
Manual of the Inverter for details on the parameters.
Name
0: The RUN Key and STOP/RESET Key on the
Digital Operator are enabled.
1: Multi-function input is enabled through the con-
trol circuit terminals.
2: RS-422A/485 communications are enabled.
3: Input is enabled from the optional Communica-
tions Unit.
0: Frequency reference adjustment
1: Frequency reference 1 (n024)
2: Frequency reference control terminal (0 to 10
V)
3: Frequency reference control terminal (4 to 20
mA)
4: Frequency reference control terminal (0 to 20
mA)
5: Pulse train reference control terminal
6: Frequency reference through RS-422A/RS-485
7: Multi-function analog voltage input (0 to 10 V)
8: Multi-function analog current input (4 to 20 mA)
9: Frequency reference input through optional
Communications Unit.
0: Decelerates to stop
1: Coasts to stop
0: Reverse enabled
1: Reverse disabled
50.0 to 400.0 Hz (0.1-Hz increments)
0.1 Hz to 10.0 Hz (0.1-Hz increments)
0: 0.1 s
1: 0.01 s
0 to 6,000 s
0 to 6,000 s
0: Detects time-over, fatal error, and the Inverter
coasts to a stop.
1: Detects time-over, detects fatal error, and the
Inverter decelerates to a stop in deceleration time
1.
2: Detects time-over, detects fatal error, and the
Inverter decelerates to a stop in deceleration time
2.
3: Detects time-over, detects nonfatal error warn-
ing, and the Inverter continues operating.
4: No time-over is detected.
0: 0.1 Hz
1: 0.01 Hz
2: Converted value based on 30,000 decimal as
maximum frequency
3: 0.1% (Maximum frequency: 100%)
Description
Section 5-3
Default
Setting
0
2
0
6
0
0
0
0
60.0 Hz
60.0 Hz
(Depends
on machine
configura-
tion.)
1.5 Hz
0.1 Hz
0
0
10.0 s
0
10.0 s
0
0
0
0
1
299