Adjusting the scanner magnification (alternative command for the maintenance mode U065)
Description
Adjusts the magnification of the original scanning.
Purpose
Make the adjustment if the magnification in the main scanning direction is incorrect.
Make the adjustment if the magnification in the auxiliary scanning direction is incorrect.
!R! KCFG "SCAN",8, #1,#2;EXIT;
Format
#1
1: Y SCAN ZOOM Scanner magnification in the main scanning direction
Parameter
2: X SCAN ZOOM Scanner magnification in the auxiliary scanning direction
#2
#1=1: Adjustable range: -32 to 127 (in 0.1% increment) (0: default)
#2=2 : Adjustable range: -25 to 25 (in 0.1% increment) (0: default)
Example: Y SCAN ZOOM set to 55, X SCAN ZOOM set to 10
!R! KCFG "SCAN",8,1,55; KCFG "SCAN",8,2,10;EXIT;