(Align the FFC wire at the main PWB side.)
65. Remove the left and right holders of the
scanner unit at Step 20, 21 and fully
open the scanner unit.
66. Align the FFC wire like the figure to the
right.
(Seven alignment ribs and one ferrite
core)
67. Insert the end of the FFC wire into the
connector YC8 on the main PWB.
68. Refit all the parts and the unit detached
in the reverse manner of the above pro-
cedures.
(Wire holder viewed from the machine right side)
1-5-81
Wire holder
Figure 1-5-132
Ferrite core
Alignment ribs
are circled in
Figure 1-5-133
FFC wire
YC8
Figure 1-5-134
2PZ-1
FFC wire
red.