Kyocera TASKalfa 266ci Service Manual page 352

Hide thumbs Also See for TASKalfa 266ci:
Table of Contents

Advertisement

Connector
Pin
1
TNSENM
YC1
Connected to
2
ERASECDR
engine PWB
3
TNSENK
4
ERASEMDR
5
DLPTHERM
6
ERASEKDR
7
+3.3V2
8
EECLK
9
GND
10
EEDATA
11
TNSENY
12
ERASEYDR
13
TNSENC
1
GND
YC2
Connected to
2
EECLK
drum PWB K
3
ERASEKDR
4
EEDATA
5
N.C.
6
+3.3V2
7
DA0
8
DA1
1
GND
YC3
Connected to
2
EECLK
drum PWB M
3
ERASEMDR
4
EEDATA
5
N.C.
6
+3.3V2
7
DA0
8
DA1
1
GND
YC4
Connected to
2
EECLK
drum PWB C
3
ERASECDR
4
EEDATA
5
N.C.
6
+3.3V2
7
DA0
8
DA1
Signal
I/O
O
Analog
I
0/24 V DC
O
Analog
I
0/24 V DC
O
Analog
I
0/24 V DC
I
3.3 V DC
I
0/3.3 V DC (pulse) EEPROM clock signal
-
-
I/O
0/3.3 V DC (pulse) EEPROM data signal
O
Analog
I
0/24 V DC
O
Analog
-
-
O
0/3.3 V DC (pulse) EEPROM clock signal
O
0/24 V DC
I/O
0/3.3 V DC (pulse) EEPROM data signal
-
-
O
3.3 V DC
-
-
-
-
-
-
O
0/3.3 V DC (pulse) EEPROM clock signal
O
0/24 V DC
I/O
0/3.3 V DC (pulse) EEPROM data signal
-
-
O
3.3 V DC
-
-
-
-
-
-
O
0/3.3 V DC (pulse) EEPROM clock signal
O
0/24 V DC
I/O
0/3.3 V DC (pulse) EEPROM data signal
-
-
O
3.3 V DC
-
-
-
-
Voltage
TS-M detection voltage
CL-C: On/Off
TS-K detection voltage
CL-M: On/Off
DEVTH detection voltage
CL-K: On/Off
3.3 V DC power from EPWB
Ground
TS-Y detection voltage
CL-Y: On/Off
TS-C detection voltage
Ground
CL-K: On/Off
Not used
3.3 V DC power to DRPWB-K
Not used
Not used
Ground
CL-M: On/Off
Not used
3.3 V DC power to DRPWB-M
Ground
Not used
Ground
CL-C: On/Off
Not used
3.3 V DC power to DRPWB-C
Not used
Ground
2-3-22
Description
2PZ

Advertisement

Table of Contents
loading