(Attaching the new ISU)
57. Fold the FFC wire of the new ISU with
the alignment to the right.
(1)Fold the FFC wire in 90 degrees at
300mm from Alignment G at the edge of
the holder passing the FFC wire to make
Alignment H.
(Or, fold it in 90 degrees on the line con-
necting the Alignment H and Alignment H'
at 33mm from H.)
(2)Fold it in 90 degrees at Alignment I at
135mm from the Alignment H' to make
Alignment J.
(3)Fold the FFC wire in 180 degrees at the
Alignment J.
(The reference length from the
Alignment J to the wire's edge is about
195mm.)
(4)Unfold the FFC wire to easily pass the
FFC wire through the ferrite core at the
next step.
58. Pass the ISU's FFC wire through the
ferrite core affixed on the scanner frame
and then pass its edge through the
aperture in the center of the scanner
frame.
I
J
135mm
(+/-1mm)
H'
300mm (+/-1mm)
H
33mm (+/-1mm)
About 195mm
FFC wire
1-5-78
180 degrees
J
Figure 1-5-127
Aperture
Ferrite core
Figure 1-5-128
2PZ-1