12. Using a 1/2" socket and a 1/2" open-end wrench, attach the bolt, nut, lock washer and two flat
washers securing leads W4, W5 and W10 to the output rectifier. See Wiring Diagram.
13. Using a 3/8" nutdriver, attach the four screws holding the case front panel to the base of the
machine.
14. Connect any previously disconnected wiring to the case front panel assembly components. Replace
any cable ties as necessary.
15. Connect plugs J1, J2, J3, J4, J5, J6 and J7 to the weld control board. See Wiring Diagram.
16. Perform the Case Cover Replacement Procedure.
17. Perform the Retest After Repair Procedure.
Figure F.24 – Weld control board plug locations