LINCOLN ELECTRIC
WELDING TERMINAL SWITCH
SETTING
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
REMOTELY CONTROLLED
WELD TERMINALS ON
Table F. 4 – Remote receptacle resistance tests
OHMMETER CONNECTION
PIN G (75B) TO PIN A (32)
PIN G (75B) TO PIN B (GND-A)
PIN G (75B) TO PIN C (2B)
PIN G (75B) TO PIN D (4B)
PIN G (75B) TO PIN E (77B)
PIN G (75B) TO PIN F (76B)
PIN G (75B) TO PIN H (21)
PIN G (75B) TO PIN I (41A)
PIN G (75B) TO PIN J (31)
PIN G (75B) TO PIN K (42A)
PIN F (76B) TO PIN A (32)
PIN F (76B) TO PIN B (GND-A)
PIN F (76B) TO PIN C (2B)
PIN F (76B) TO PIN D (4B)
PIN F (76B) TO PIN E (77B)
PIN F (76B) TO PIN H (21)
PIN F (76B) TO PIN I (41A)
PIN F (76B) TO PIN J (31)
PIN F (76B) TO PIN K (42A)
PIN E (77B) TO PIN A (32)
PIN E (77B) TO PIN B (GND-A)
PIN E (77B) TO PIN C (2B)
PIN E (77B) TO PIN D (4B)
PIN E (77B) TO PIN H (21)
PIN E (77B) TO PIN I (41A)
PIN E (77B) TO PIN J (31)
PIN E (77B) TO PIN K (42A)
PIN C (2B) TO PIN D (4B)
PIN C (2B) TO PIN D (4B)
Ranger® 305G EFI Service Manual
EXPECTED READING
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
500,000 (500K) OHMS OR HIGHER
RESISTANCE SHOULD BE VERY
LOW. THE OHMMETER SHOULD
READ ABOUT THE SAME VALUE AS
ONE WOULD GET BY TOUCHING
THE METER PROBES TOGETHER.