Sony SRX-R510 Operating Instructions Manual page 41

Digital cinema dual system
Table of Contents

Advertisement

• The content displayed on the calibration camera's
display during calibration using SPLs differs from that
displayed during manual calibration. (only "REMOTE
CTRL MODE" appears at the center of the display.)
• If the calibration camera's power supply is cut during
SPL execution, server operations may become unstable.
1
Create the calibration SPL.
1 Perform steps 1 to 4 in "Creating an SPL"
(page 26) to create a new SPL.
2 Add the calibration CPL to the SPL.
Select the [CPL] radio button, and select the
calibration CPL from the list, and then tap
[Insert].
3 Add the function switching cue to the SPL.
Select the [Cue] radio button, and select the
function switching cue for calibration from the
list, and then tap [Insert].
Set the offset to "00:00:30."
4 Add the calibration execution cue to the SPL.
Select the calibration start cue
(PCAB_start_short) from the list, and then tap
[Insert].
Set the offset to "00:01:00."
2
Register the calibration SPL that you created to the
schedule.
Select the appropriate calibration frequency (daily,
weekly, etc.).
For details, see "Creating a Schedule" (page 30).