Periodic Calibration Using Spls - Sony SRX-R510 Operating Instructions Manual

Digital cinema dual system
Table of Contents

Advertisement

6
Tap F3 [START].
A L I G N M E N T > A D J
C A M E R A
A D J U S T M E N T
D O N E !
S T A R T
C A L I B R A T I O N ?
Q U I T
Calibration starts automatically.
During calibration, the target frame will automatically
move to the current point of calibration.
A L I G N M E N T > C A L
A B O R T
Caution
• Do not move the calibration camera while
calibration is in progress.
• Prevent obstructions from entering the space
between the calibration camera and screen.
7
When the "Convergence Adjust" test pattern appears,
check the calibration results.
Confirm the color of the markers on the calibration
points of the captured calibration image.
Green: Calibration successful.
Amber: Calibration errors exceed the specific margin
of error. Be sure to verify the image visually.
Red: Divergence exceeds the scope of electronic
calibration. Adjust the projectors manually, and
then try performing calibration again.
8
S T A R T
9
3 0 %
10

Periodic Calibration Using SPLs

You can create a calibration SPL and register it to a
schedule to perform periodic calibration with the
calibration camera. (Only for Ver.1.50 or later.)
Notes
• A calibration CPL must be ingested beforehand.
• For details on the CPLs to be used, contact qualified
Sony service personnel.
40
Tap F3 [ENTER].
A L I G N M E N T > R E S U L T
S C O P E
Tap F3 [SAVE].
A L I G N M E N T > C O N F I R M
S A V E
A L I G N M E N T
T O
P J T
F U N C T I O N S ?
R E T U R N
Q U I T
To quit the application without saving, tap F2 [QUIT].
Tap F1 [QUIT] to quit the application.
A L I G N M E N T > S A V E D
A L I G N M E N T
S U C C E S F U L L Y
Q U I T
E N T E R
D A T A
S A V E
D A T A
W A S
S A V E D