Codeplug Help - Motorola iDEN i930 Field Service Manual

Basic and field level test procedures
Hide thumbs Also See for iDEN i930:
Table of Contents

Advertisement

1. Insert the 17-pin connector on the data cable to the 17-pin connector located at the base of the
unit.
2. Attach the other end of the data cable to the RS-232 port or USB port on the RSS computer
workstation that is used for testing purposes.
Refer to any relevant Radio Service Software Read-Me's or active iDEN Service Bulletins for more
information on setting up your test computer as an RSS workstation.
NOTE: For faster codeplug reading using an RS-232 connector, enable the QuickComm feature in
the RSS configuration setup.
6.5.1

Codeplug Help

If the codeplug is corrupted, the unit displays a SELF CHECK ERROR 0800 message. The
procedure for repairing a corrupted codeplug is described in the RSS online Help System.
Equipment Required: Computer workstation with RSS installed, data cable RS232 or USB,
68P80401P03-O
BASIC LEVEL TEST MODES AND PROCEDURES: Connecting the Unit to the RSS Workstation
Figure 6-1. Data Cable Programming Setup
reference unit (must be the same model as the problem unit).
6-9