Led Frequency; Cell Order; Calibrated White; White Balance - Chauvet COLORado PXL Curve 12 User Manual

Table of Contents

Advertisement

Operation

LED Frequency

This option changes the Pulse Width Modulation (PWM) frequency of the LEDs on the
COLORado PXL Curve 12.
1. Go to the Setup main level.
2. Go to the PWM Option main level.
3. Select PWM frequency (600Hz, 1200Hz, 2000Hz, 4000Hz, 6000Hz, or 25Khz).

Cell Order

To set how the light is activated, follow the instructions below:
1. Go to the Setup main level.
2. Select Cell Order.
3. Choose 1–12 (light activates from left to right) or 12–1 (light activates from right to left).

Calibrated White

When activated, calibrated white sets the light output temperature to 7500K. To set the calibrated white
setting, do the following:
1. Go to the Setup main level.
2. Select Calibrated White.
3. Select ON (activates calibrated white), OFF (deactivates calibrated white), or Custom (adjust light
output temperature using the White Balance setting).

White Balance

To set the maximum values of a given LED color to create a white light output, follow the instructions below:
1. Go to the Setup main level.
2. Select White Balance.
3. Select the color value to be changed (Red, Green, Blue, or White).
4. Set the color value, 000–255.

Preset Functions

The COLORado PXL Curve 12 has three presets. Every time a settings is changed in the fixture, the
current preset is updated to include that change. To load a preset, do the following:
1. Go to the Setup main level.
2. Select Preset Select.
3. Select the preset to load (Preset A, Preset B, or Preset C).
4. The selected preset will load, and all changes made to the settings will save to that preset.
Presets can be uploaded to other COLORado PXL Curve 12 using a DMX connection. To do so:
1. Connect the DMX Out of the product that has the desired presets to the DMX In of the product to
be updated.
2. Power on both products.
3. On the product with the desired presets, go to the Setup main level.
4. Select Preset Sync.
5. Select NO (do not upload settings) or YES (upload settings).

Reset Functions

To reset the tilt, zoom, or all functions as if from startup, follow the instructions below:
1. Go to the Setup main level.
2. Select Reset Function.
3. Select the function to be reset (Tilt, Zoom, or All).
4. Select NO (do not reset) or YES (reset).

Factory Reset

To restore the COLORado PXL Curve 12 to factory default settings, do the following:
1. Go to the Setup main level.
2. Select Factory Settings.
3. Select NO (do not reset) or YES (reset to factory default settings).
COLORado PXL Curve 12 User Manual Rev. 4
35

Advertisement

Table of Contents
loading

Table of Contents