5. Maintenance

Product Maintenance

To maintain optimum performance and minimize wear, clean this product frequently. Usage and
environment are contributing factors in determining the cleaning frequency.
Clean this product at least twice a month. Dust build-up reduces light output performance and can cause
overheating. This can lead to reduced light source life and increased mechanical wear.
To clean the product:
1.
Unplug the product from power.
2.
Wait until the product is at room temperature.
3.
Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external
vents.
4.
Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl
alcohol.
5.
Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
6.
Softly drag any dirt or grime to the outside of the transparent surface.
7.
Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Avoid spinning the cooling fans using compressed air to prevent damage.

Torque Measurements

To maintain the IP rating when reassembling the product, use the given torque measurements for each of
the following screws and bolts:
Fixture Parts
Feet
Omega bracket holders
Bottom allen key (not feet)
Screws for safety cable point
Screws around power and data points
Connector plate allen key screws
Fuse
Front display bump-out allen screws
Allen screws around display
Allen screws holding yokes to base
Allen screws for alignment pin holder
Allen screws around lens covers

Vacuum Test Measurements

Use the IP Tester from Chauvet Professional to ensure the product has been reassembled correctly by
following the information below:
Parameters
Method
Test pressure
Test duration
PASS state leak pressure
38
Torque Rating (Kgf.cm)
9.2
12.2
9.2
15.3
3.6
16.3
7.1
15.3
9.2
15.3
12.2
12.2
2.18 kPa
60 seconds
<0.02 kPa
COLORado PXL Curve 12 User Manual Rev. 4
Maintenance
Torque Rating (lgb.in)
7.9
10.6
7.9
13.3
3.1
14.1
6.2
13.3
7.9
13.3
10.6
10.6
Values
Positive