5-14. Factory Parameter Defaults And Range And Resolution

Parameter
MEMORY
PROCESS
**Stick OCV
OUTPUT
**RMT 2T
A MAIN / PEAK
DC TIG
DC STICK
Spot Time
***Weld Time
PULSER
PPS
PEAK t
BKGND A
**Display PPP While Pulse Welding
SEQUENCER
INITIAL A
***Initial Time
INITIAL SLOPE t
FINAL SLOPE t
FINAL A
***Final Time
ADJUST
PREFLOW
POST FLOW
DIG
**Impulse HF Start parameters for each program (1-4)
DC:
** Parameter adjusted using a power up configuration only
*** Parameter used with the automation option (LX models only)
Amperage
Time
Default
1
TIG HF Impulse
Low OCV
RMT STD
2T
RMT 2T can be reconfigured for: 2T / 4T / Mini Logic
/ 4T Momentary / Spot (see Section 6-2C)
150 A
110 A
1.0 S
0 S
Off
100 Hz
40%
25%
Off
20 A
0 S
0 S
0 S
5 A
0 S
0.2 S
10.0 S
0.0 − 50.0 Seconds @ 0.2 Second Resolution
30%
30 A
3 mS
Range And Resolution
1−4
TIG HF Impulse / TIG Lift / Stick
Low OCV / Normal OCV
RMT STD / RMT 2T / ON
5 − 300 Amps
5 − 300 Amps
0.1 − 25.0 Seconds
Dual Range And Resolution
0.0 − 99.9 / 100 − 999 Seconds
ON / OFF
Dual Range And Resolution
0.1 − 9.9 / 10 − 500 Hertz
5 − 95 Percent
5 − 95 Percent
Off / On
5 − 300 Amps
0.0 − 25.0 Seconds
0.0 − 25.0 Seconds
0.0 − 25.0 Seconds
5 − 300 Amps
0.0 − 25.0 Seconds
0.0 − 25.0 Seconds
0 − 100 Percent
5 − 200 Amps
1 − 200 Milliseconds