12-2. Electrode and Amperage Selection Chart

3/32
1/8
6010
5/32
&
3/16
6011
7/32
1/4
1/16
5/64
3/32
1/8
6013
5/32
3/16
7/32
1/4
3/32
1/8
5/32
7014
3/16
7/32
1/4
3/32
1/8
5/32
7018
3/16
7/32
1/4
3/32
1/8
5/32
7024
3/16
7/32
1/4
3/32
1/8
Ni-Cl
5/32
3/16
3/32
1/8
308L
5/32
6010
EP
ALL
DEEP
MIN. PREP, ROUGH
6011
EP
ALL
DEEP
6013
EP,EN
ALL
LOW
7014
EP,EN
ALL
MED
7018
EP
ALL
LOW
FLAT
7024
EP,EN
HORIZ
LOW
FILLET
NI-CL
EP
ALL
LOW
308L
EP
ALL
LOW
*EP = ELECTRODE POSITIVE (REVERSE POLARITY)
EN = ELECTRODE NEGATIVE (STRAIGHT POLARITY)
HIGH SPATTER
GENERAL
SMOOTH, EASY,
FAST
LOW HYDROGEN,
STRONG
SMOOTH, EASY,
FASTER
CAST IRON
STAINLESS